Common Spa Error Codes

“Don’t let pool Cowboys near your spa! Call the experts & Get it right the first time”
Delivering a New Sp

Spa Error Codes - Spa Problems

Check the error code on the Spa Touch pad and check our list below

 

Alphabetical Error Code List

BJ2P Hi-Limit - water temp too high

C4.4 Hi- Limit

Cd, CLd Freeze Condition

CE 01 Stuck Touchpad button

CE 02 No controller Data Communication

CE 03 Temperature sensor fault

CE 04 Water Sensor/Pressure switch fault

CE 05 Over Temperature Condition

CE 06 High Limit manual reset Klixon tripped

CE 07 Stuck Relay

CE 08 Temp Sensor Fault - (Spaquip Digital 2000 MK1 sensor)

CE 09 Water Prime Fault - Lack of water

CoLd spa heater temp below 40F

Cool, COOL, COL Water is 11C below set point - not a fault

DR, dr, dy Heater dry - insufficient water fault

Er0, Er1 Temperature sensor faulty

Er2, Er3 Hi-Limit fault

Er4 Flow/Pressure switch short circuit

Error 3 - SpaquipStuck touchpad button

Error 4 Water sensor fault

Error 5 Over temperature

Error 6 Klixon Tripped - over temp

Error 7 Stuck Relay

Error 8 Temperature sensor fault

Err Software Program Fault

E### pH probe out of calibration

E0 Short circuit temperature sensor

E1 Open circuit temperature sensor

E2 short circuit/closed high limit sensor

E3 Open circuit high limit sensor

E4 Short circuit/closed pressure/flow switch

E7 Improper electrical connection

FLO, Flo, FL1Flow/pressure switch open circuit-lack of flow/pressure

or for Sundance/Spa Builders/Balboa - Flow switch is closed circuit

FLC, FL2 Flow/pressure switch closed circuit - debris in switch, perforated diaphragm, faulty

FL Pressure/flow switch failure

FLO (flashing) Flow switch open circuit - Sundance/Spa Builders/ Balboa

FrE, Fr, FP Freeze Condition

HiLi, HLEr Water temperature above acceptable range

HL,HFL,HH,OHH High limit sensor reading 45-48C, or above - check flow

HoldPanel buttons pressed too many times too quickly

HOTPCB thermistor above 45C

H2O Water Prime Fault - lack of water

ICE, ICFreeze Condition

ILOC Interlock failure, also caused by faulty ozonators, pumps and equipment

L FLow Flow Fault

LO Freeze Condition

LOC Control Panel functions Locked

LS=0, LS=S Multiple causes - open circuit sensor, faulty panel connection, improper voltage, etc

L1 Panel Lock

L2 Panel Lock

OH, OHS, oH Overheat Condition 43-45C

OP Open circuit sensor

pd, PdRunning on battery - power supply interrupted

PLUGSundance/Spa Builders Service Technician's Test Plug accidentally left connected to PCB

PnL, nlCommunication disrupted between touchpad and PCB

PrSystem Priming - not a fault

Prh High limit sensor fault

Prr Temperature sensor fault

PS Flow/Pressure switch failure

PSoC,PSoL,PSoH Pressure switch open circuit with Circulating, Low Speed,

or High speed pumps

SA, SnA, SnH,

Sb, Snb,

SntSensor Open Circuit or faulty - SnH - Hi Limit,

SnT - Temp sensor

SEoP Sensor Open Circuit

SESH Sensor Short Circuit

SH Short circuit sensor

Sn, SnS Sensors out of balance

Sn1 High Limit sensor fault

Sn2, Sn3 Temperature sensor fault

SS=0, SS=S Multiple causes - open circuit sensor, faulty panel connection, improper voltage, etc.

To ETime Out Error

- 01 Hi-Limit

- 02 Temp sensor fault

- 03 Flow/pressure switch open

- 04 Flow/Pressure switch closed

- 07 Hi-limit

131 Hi-limit

- - Temperature unknown - displayed at power up for 2 minutes - not a fault

- - - - , - Sundance/Spa Builders - 'Watchdog' - 48C reached, electronic fault, shuts system down. Major

Fault

* * * (3 flashing dots under temp display)Flow/Pressure switch either Open or Closed Circuit

* * * (as above, plus illuminated red LED on PCB)High Limit Fault

Spa Controller Brand Error Codes

Balboa Error Codes

pd : Power supply, unit running on battery backup

OH : Sensors reading 45 Degrees

Flo : Improper flow or pressure switch malfunction

Cool : Water temp 20 degrees below set point

ICE : Potential freeze condition has been detected

Sn1 : Hi-limit sensor malfunction

Sn3 : Temp sensor malfunction

ILOC : Interlock failure - possible pump or ozone spike

Sundance Error Codes

ILOC : Interlock failure - possible pump or ozone spike

FLO : Pressure switch malfunction

Hold : Panel buttons pressed to many times to quickly

HOT : PCB temperature above acceptable limit - air blower on

ICE : Potential freeze condition

Pnl : Communication between PCB and panel interrupted

Sn1 : Hi-limit sensor failure

Sn3 : Temp sensor failure

Gecko Error Codes

FLO : Pressure switch failure, switch open

FLC : Pressure switch failure, switch closed

Prr : Temp sensor failure

Prh : Hi-limit sensor failure

HL : Sensor measuring 45 degrees

FrE : Possible freeze condition detected

Spa Quip Error Codes

err 1 (H20) : Prime Failed

err 3 : Stuck Button

err 4 : No Water Sensor

err 5 : Overtemperature

err 6 : Thermal Cut Out Tripped

err 7 : Stuck Relay

err 8 : No Temperature Data

01 : Stuck Button

02 : No Controller Data

03 : Temperature Sensor

04 : Water Sensor

05 : Spa Over Temperature

06 : Heater Thermal Cut Out

07 : Stuck Heater Relay

09 : Water Prime Failed

Hurricane Error Codes

PS : Flow or pressure switch failure

SH : Shorted sensor

OP : Open Sensor Degrees

LO : Temp below 4 degrees - freeze

HL : Temp above 45 degrees

OH : Spa temp exceeds acceptable limits

FLO : Flow problem

ICE : Freeze condition detected

SN1 : Hi-limit sensor failure

SN2 : Temp sensor failure

Hercules Error Codes

OH : Spa temp exceeds acceptable limits

FLO : Flow problem

ICE : Freeze condition detected

SN1 : Hi-limit sensor failure

SN2 : Temp sensor failure

Brett Error Codes

OH : Temp exceeds 45 degrees

Fr : Freeze condition - temp below 40 degrees

FL : Pressure switch failure

EO : Shorted temp sensor

E1 : Open temp sensor

E2 : Shorted hi-limit sensor

E3 : Open hi-limit sensor

E4 : Shorted flow switch

E7 : Improper electrical connection

Vita Error Codes

HiLi : Water temp over acceptable limit

BJ2P : Pump/Blower purge - normal condition

FP : Freeze protect-temp under acceptable condition

SS=0;SS=S;LS=O;LS=S : Multiple causes; open sensors, bad connection to

panel, improper voltage, etc.

Flashing Light Error Codes

1 flash - 3 second gapHigh Limit fault

2 flashes - 3 second gapPressure/Flow switch short circuit

3 flashes - 3 second gapPressure/Flow switch open circuit

4 flashes - 3 second gapOpen circuit Sensor(s)

Flash - 1 second on, 1 second off Same as OH

Flash - briefly OFF once per second Same as Sn1 or Sn3

Flash - briefly ON once per second Same as FLC

Blinking Power Indicator Light - HydromateHigh Limit tripped or, sensor fault

1 flash per second - onga 4352,53,95,etcPressure switch open circuit - could also be motor, or motor

thermal overload

3 flashes per second - onga 4352,53, 95, etcElectronic fault - sensor (most common cause) or PCB

Green flashes - Spaquip Pulsar/2095 seriesWater sensor fault - lack of water

Red/Green alternate flashes Temperature sensor fault, open circuit, or high limit tripped - push Reset

Rod

We accept:
For Touchpad Instruction Manuals - Click Here
  The Gas Heater & Electronic specialists more Manufacturer’s & Pool Shops recommend.   We are on the lookout for a well- presented, qualified service person for other areas of Melbourne. Please email us  if you are interested.   We now to regular servicing and chemical supplies online! Use Promo Code “Peninsula” for FREE SHIPPING!
Our trading terms are located on our website and the trading terms shall form part of the contract which governs the relationship between you and us”.
Gecko, Balboa, Aquaflo, SpaNET, SpaQuip, Hurlcon, Astralpool, Pentair, and more…

Spa Error Codes - Spa Problems

Check the error code on the Spa Touch pad

and check our list below

Touchpad Manuals / Instructions

 

Alphabetical Error Code List

BJ2P Hi-Limit - water temp too high

C4.4 Hi- Limit

Cd, CLd Freeze Condition

CE 01 Stuck Touchpad button

CE 02 No controller Data Communication

CE 03 Temperature sensor fault

CE 04 Water Sensor/Pressure switch fault

CE 05 Over Temperature Condition

CE 06 High Limit manual reset Klixon

tripped

CE 07 Stuck Relay

CE 08 Temp Sensor Fault - (Spaquip Digital

2000 MK1 sensor)

CE 09 Water Prime Fault - Lack of water

CoLd spa heater temp below 40F

Cool, COOL, COL Water is 11C below set

point - not a fault

DR, dr, dy Heater dry - insufficient water

fault

Er0, Er1 Temperature sensor faulty

Er2, Er3 Hi-Limit fault

Er4 Flow/Pressure switch short circuit

Error 3 - SpaquipStuck touchpad button

Error 4 Water sensor fault

Error 5 Over temperature

Error 6 Klixon Tripped - over temp

Error 7 Stuck Relay

Error 8 Temperature sensor fault

Err Software Program Fault

E### pH probe out of calibration

E0 Short circuit temperature sensor

E1 Open circuit temperature sensor

E2 short circuit/closed high limit sensor

E3 Open circuit high limit sensor

E4 Short circuit/closed pressure/flow switch

E7 Improper electrical connection

FLO, Flo, FL1Flow/pressure switch open

circuit-lack of flow/pressure

or for Sundance/Spa Builders/Balboa - Flow

switch is closed circuit

FLC, FL2 Flow/pressure switch closed

circuit - debris in switch, perforated

diaphragm, faulty

FL Pressure/flow switch failure

FLO (flashing) Flow switch open circuit -

Sundance/Spa Builders/ Balboa

FrE, Fr, FP Freeze Condition

HiLi, HLEr Water temperature above

acceptable range

HL,HFL,HH,OHH High limit sensor reading

45-48C, or above - check flow

HoldPanel buttons pressed too many times

too quickly

HOTPCB thermistor above 45C

H2O Water Prime Fault - lack of water

ICE, ICFreeze Condition

ILOC Interlock failure, also caused by faulty

ozonators, pumps and equipment

L FLow Flow Fault

LO Freeze Condition

LOC Control Panel functions Locked

LS=0, LS=S Multiple causes - open circuit

sensor, faulty panel connection, improper

voltage, etc

L1 Panel Lock

L2 Panel Lock

OH, OHS, oH Overheat Condition 43-45C

OP Open circuit sensor

pd, PdRunning on battery - power supply

interrupted

PLUGSundance/Spa Builders Service

Technician's Test Plug accidentally left

connected to PCB

PnL, nlCommunication disrupted between

touchpad and PCB

PrSystem Priming - not a fault

Prh High limit sensor fault

Prr Temperature sensor fault

PS Flow/Pressure switch failure

PSoC,PSoL,PSoH Pressure switch open

circuit with Circulating, Low Speed,

or High speed pumps

SA, SnA, SnH,

Sb, Snb,

SntSensor Open Circuit or faulty - SnH - Hi

Limit,

SnT - Temp sensor

SEoP Sensor Open Circuit

SESH Sensor Short Circuit

SH Short circuit sensor

Sn, SnS Sensors out of balance

Sn1 High Limit sensor fault

Sn2, Sn3 Temperature sensor fault

SS=0, SS=S Multiple causes - open circuit

sensor, faulty panel connection, improper

voltage, etc.

To ETime Out Error

- 01 Hi-Limit

- 02 Temp sensor fault

- 03 Flow/pressure switch open

- 04 Flow/Pressure switch closed

- 07 Hi-limit

131 Hi-limit

- - Temperature unknown - displayed at

power up for 2 minutes - not a fault

- - - - , - Sundance/Spa Builders - 'Watchdog'

- 48C reached, electronic fault, shuts system

down. Major Fault

* * * (3 flashing dots under temp

display)Flow/Pressure switch either Open or

Closed Circuit

* * * (as above, plus illuminated red LED on

PCB)High Limit Fault

Spa Controller Brand Error Codes

Balboa Error Codes

pd : Power supply, unit running on battery

backup

OH : Sensors reading 45 Degrees

Flo : Improper flow or pressure switch

malfunction

Cool : Water temp 20 degrees below set

point

ICE : Potential freeze condition has been

detected

Sn1 : Hi-limit sensor malfunction

Sn3 : Temp sensor malfunction

ILOC : Interlock failure - possible pump or

ozone spike

Sundance Error Codes

ILOC : Interlock failure - possible pump or

ozone spike

FLO : Pressure switch malfunction

Hold : Panel buttons pressed to many times

to quickly

HOT : PCB temperature above acceptable

limit - air blower on

ICE : Potential freeze condition

Pnl : Communication between PCB and

panel interrupted

Sn1 : Hi-limit sensor failure

Sn3 : Temp sensor failure

Gecko Error Codes

FLO : Pressure switch failure, switch open

FLC : Pressure switch failure, switch closed

Prr : Temp sensor failure

Prh : Hi-limit sensor failure

HL : Sensor measuring 45 degrees

FrE : Possible freeze condition detected

Spa Quip Error Codes

err 1 (H20) : Prime Failed

err 3 : Stuck Button

err 4 : No Water Sensor

err 5 : Overtemperature

err 6 : Thermal Cut Out Tripped

err 7 : Stuck Relay

err 8 : No Temperature Data

01 : Stuck Button

02 : No Controller Data

03 : Temperature Sensor

04 : Water Sensor

05 : Spa Over Temperature

06 : Heater Thermal Cut Out

07 : Stuck Heater Relay

09 : Water Prime Failed

Hurricane Error Codes

PS : Flow or pressure switch failure

SH : Shorted sensor

OP : Open Sensor Degrees

LO : Temp below 4 degrees - freeze

HL : Temp above 45 degrees

OH : Spa temp exceeds acceptable limits

FLO : Flow problem

ICE : Freeze condition detected

SN1 : Hi-limit sensor failure

SN2 : Temp sensor failure

Hercules Error Codes

OH : Spa temp exceeds acceptable limits

FLO : Flow problem

ICE : Freeze condition detected

SN1 : Hi-limit sensor failure

SN2 : Temp sensor failure

Brett Error Codes

OH : Temp exceeds 45 degrees

Fr : Freeze condition - temp below 40

degrees

FL : Pressure switch failure

EO : Shorted temp sensor

E1 : Open temp sensor

E2 : Shorted hi-limit sensor

E3 : Open hi-limit sensor

E4 : Shorted flow switch

E7 : Improper electrical connection

Vita Error Codes

HiLi : Water temp over acceptable limit

BJ2P : Pump/Blower purge - normal

condition

FP : Freeze protect-temp under acceptable

condition

SS=0;SS=S;LS=O;LS=S : Multiple causes;

open sensors, bad connection to

panel, improper voltage, etc.

Flashing Light Error Codes

1 flash - 3 second gapHigh Limit fault

2 flashes - 3 second gapPressure/Flow

switch short circuit

3 flashes - 3 second gapPressure/Flow

switch open circuit

4 flashes - 3 second gapOpen circuit

Sensor(s)

Flash - 1 second on, 1 second off Same as

OH

Flash - briefly OFF once per second Same

as Sn1 or Sn3

Flash - briefly ON once per second Same as

FLC

Blinking Power Indicator Light -

HydromateHigh Limit tripped or, sensor fault

1 flash per second - onga

4352,53,95,etcPressure switch open circuit -

could also be motor, or motor thermal

overload

3 flashes per second - onga 4352,53, 95,

etcElectronic fault - sensor (most common

cause) or PCB

Green flashes - Spaquip Pulsar/2095

seriesWater sensor fault - lack of water

Red/Green alternate flashes Temperature

sensor fault, open circuit, or high limit

tripped - push Reset Rod